2 Parameters
2.2 List of parameters
SINAMICS G130/G150
926 List Manual (LH2), 04/2014, A5E03263479A
Recommend.: This is used to check whether the safety message buffer has been read out consistently.
Dependency: Refer to: r9747, r9748, r9749, p9752, r9753, r9754, r9755, r9756
Description: Displays the component of the safety message that has occurred.
Note: Value = 0: Assignment to a component not possible.
Description: Displays the numbers of safety messages that have occurred.
Dependency: Refer to: r9744, r9748, r9749, p9752, r9753, r9754, r9755, r9756
Note: The messages type "safety message" (Cxxxxx) are entered in the message fault buffer.
Message buffer structure (principle):
r9747[0], r9748[0], r9749[0], r9753[0], r9754[0], r9755[0], r9756[0] --> Actual message case, safety message 1
...
r9747[7], r9748[7], r9749[7], r9753[7], r9754[7], r9755[7], r9756[7] --> Actual message case, safety message 8
r9747[8], r9748[8], r9749[8], r9753[8], r9754[8], r9755[8], r9756[8] --> 1st acknowledged message case, safety
message 1
...
r9747[15], r9748[15], r9749[15], r9753[15], r9754[15], r9755[15], r9756[15] --> 1st acknowledged message case,
safety message 8
...
r9747[56], r9748[56], r9749[56], r9753[56], r9754[56], r9755[56], r9756[56] --> 7th acknowledged message case,
safety message 1
...
r9747[63], r9748[63], r9749[63], r9753[63], r9754[63], r9755[63], r9756[63] --> 7th acknowledged message case,
safety message 8
Description: Displays the relative system runtime in milliseconds when the safety message occurred.
Dependency: Refer to: r9744, r9747, r9749, p9752, r9753, r9754, r9755, r9756
r9745[0...63] SI components / SI comp
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9747[0...63] SI message code / SI msg_code
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9748[0...63] SI message time received in milliseconds / SI t_msg recv ms
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]