SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
703
2 Parameters
2.2 List of parameters
Description: Displays the maximum absolute deviation of the measured current actual values of phase V from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7021.
Dependency: Refer to: r7021, r7025, r7027
Description: Displays the maximum absolute deviation of the measured current actual values of phase W from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7022.
Dependency: Refer to: r7022, r7025, r7026
Description: Displays the deviation of the measured DC link voltage from the average value.
The maximum deviation from the average value is displayed in r7031.
Dependency: Refer to: r7031
Description: Displays the maximum absolute deviation of the measured DC link voltage from the average value.
The deviation of the individual voltages from the average value is displayed in r7030.
Dependency: Refer to: r7030
r7026 CO: Par_circuit max. deviation currents phase V / Phase V Max i_dev
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7027 CO: Par_circuit max. deviation currents phase W / Phase W Max i_dev
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7030[0...n] CO: Par_circuit DC link voltage deviation / Vdc deviation
B_INF (Parallel),
VECTOR_G (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7031 CO: Par_circuit DC link voltage maximum deviation / Vdc deviation max.
B_INF (Parallel),
VECTOR_G (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]

Table of Contents

Other manuals for Siemens SINAMICS G150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G150 and is the answer not in the manual?

Siemens SINAMICS G150 Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G150
CategoryMedia Converter
LanguageEnglish

Related product manuals