SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
849
2 Parameters
2.2 List of parameters
Description: Sets the tolerance for the crosswise data comparison of the actual position between the two monitoring channels.
For encoderless motion monitoring functions, the tolerance must be set to a higher value (12 degrees rotary, 1 mm
linear).
Dependency: Refer to: p9542
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: For a linear axis, the tolerance is internally limited to 10 mm.
For a "linear axis with rotating motor" and factory setting of p9320, p9321 and p9322, the factory setting of p9342
corresponds to a position tolerance of 36 ° on the motor side.
Description: Sets the factor to increase the tolerance for the crosswise data comparison of the actual position between the two
monitoring channels while the gearbox stage is being switched over.
This factor is effective when actual value synchronization is activated and when deactivated.
Depending on the following tolerance, the following is obtained:
- actual value synchronization activated: p9549 * p9543
- actual value synchronization deactivated: p9542 * p9543
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Description: Sets the tolerance for checking the actual values.
For an incremental encoder, the actual values are checked after referencing; for an absolute encoder, when
switching on.
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: A change only becomes effective after a POWER ON.
For linear axes, the maximum value is limited to 1 mm.
Description: Sets the tolerance for checking the actual values.
p9342 SI Motion act val comparison tol (crosswise) (Motor Module) / SI Mtn actV tol MM
VECTOR_G (Safety
rot)
Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.0010 [°] 360.0000 [°] 0.1000 [°]
p9343 SI Motion gearbox switching position tolerance (MM) / SI Mtn grbx tol MM
VECTOR_G Can be changed: C2(95) Calculated: - Access level: 3
Data type: Integer32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 1000 1
p9344 SI Motion actual value comparison tolerance (referencing) (MM) / SI mtn ref tol MM
VECTOR_G Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.0000 [mm] 36.0000 [mm] 0.0100 [mm]
p9344 SI Motion actual value comparison tolerance (referencing) (MM) / SI mtn ref tol MM
VECTOR_G (Safety
rot)
Can be changed: C2(95) Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.0000 [°] 36.0000 [°] 0.0100 [°]

Table of Contents

Other manuals for Siemens SINAMICS G150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G150 and is the answer not in the manual?

Siemens SINAMICS G150 Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G150
CategoryMedia Converter
LanguageEnglish

Related product manuals