2 Parameters
2.2 List of parameters
SINAMICS G130/G150
146 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the stator leakage time constant.
Note: The value is calculated from the total of all leakage inductances (p0233*, p0353, p0356, p0358) divided by the total of
all motor resistances (p0350, p0352, p0354). The temperature adaptation of the resistances is not taken into
account.
* only applies for VECTOR (r0107).
Description: Displays the stator leakage time constant quadrature to the rotor direction (q axis).
Note: The value is calculated from the total of all leakage inductances (p0233, p0356, p0359) divided by the total of all
motor resistances (p0350, p0352, p0355).
The temperature adaptation of the resistances is not taken into account.
Description: Sets the rated no-load current (I_F0) for the excitation.
Description: Setting the rated current (I_F) of the controlled excitation rectifier (DC master).
Description: Sets the starting point of the current-dependent current controller adaptation where the current controller gain p1715
is effective.
r0386[0...n] Motor stator leakage time constant / Mot T_stator leak
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r0387[0...n] Motor stator leakage time constant q axis / Mot T_Sleak /T_Sq
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
p0389[0...n] Excitation rated no-load current / Exc I_noload_rated
VECTOR_G Can be changed: C2(1, 3) Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [A] 10000.00 [A] 0.00 [A]
p0390[0...n] Rated excitation current / Exc I_rated
VECTOR_G Can be changed: C2(1, 3) Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [A] 10000.00 [A] 0.00 [A]
p0391[0...n] Current controller adaptation starting point KP / I_adapt pt KP
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_REG Access level: 3
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6714
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [Arms] 6000.00 [Arms] 0.00 [Arms]