2 Parameters
2.2 List of parameters
SINAMICS G130/G150
62 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the slip frequency for induction motors (ASM).
Description: Display and connector output for the output frequency of the Motor Module.
Dependency: Refer to: r0024
Note: The output frequency is available smoothed (r0024) and unsmoothed (r0066).
Description: Display and connector output for the maximum output current of the power unit.
Dependency: The maximum output current is determined by the parameterized current limit and the motor and converter thermal
protection.
Refer to: p0290, p0640
Description: Displays the DC current in the DC link.
Dependency: Refer to: r0027
Notice: For Basic Line Modules of chassis format, the displayed value is invalid as these units do not have any current
sensing.
Note: The DC current in the DC link is available smoothed (r0027) and unsmoothed (r0068).
r0065 Slip frequency / f_Slip
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6310, 6700,
6727, 6730, 6732
P-Group: Displays, signals Units group: 2_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r0066 CO: Output frequency / f_outp
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 5300, 5730,
6300, 6310, 6730, 6731, 6799
P-Group: Displays, signals Units group: 2_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r0067 CO: Output current maximum / I_outp max
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 5722, 6300,
6301, 6640
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0068 CO: DC current in the DC link / Idc DC link
B_INF Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8014, 8750
P-Group: Displays, signals Units group: 6_4 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting