2 Parameters
2.2 List of parameters
SINAMICS G130/G150
404 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the excitation current actual value that is read in.
Dependency: Refer to: p0390
Description: Sets the minimum excitation current.
This means that negative excitation currents can be avoided.
Description: Sets the gain factor for the minimum excitation current, closed-loop control.
This is active if the excitation current is below 75 % of p1642.
Dependency: Refer to: p1642
Description: Displays the output of the excitation current monitoring for separately excited synchronous motors.
Description: Sets the signal source for the individual feedback signals from the excitation.
r1641 Excitation current actual value / I_exc_act val
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6727, 8018
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
p1642[0...n] Minimum excitation current / Min I_exc
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.1 [%] 50.0 [%] 5.0 [%]
p1643[0...n] Minimum excitation current closed-loop control gain factor / I_exc_min Kp
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 4
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 5.00 0.40
r1644 CO: Excitation current monitoring output / I_exc_monit outp
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
p1645[0...7] BI: Excitation feedback signals signal source / Exc FS S_src
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 6495
P-Group: Commands Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
- - [0...6] 1
[7] 0