EasyManuals Logo
Home>Tektronix>Test Equipment>DPO70000 Series

Tektronix DPO70000 Series Programmer's Manual

Tektronix DPO70000 Series
733 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #317 background imageLoading...
Page #317 background image
Commands Listed in Alphabetical Order
MASK:FILTer
This command sets or returns whether the selected digital lter will be run on
the waveform data. The lter s imulates optical hardware. That is, it simulates
different ha
rdware for each of several different optical standards.
The digital lter runs on OC1, OC3, OC12, OC48, FC133, FC266, FC531,
FC1063, FC2
125Draft, Gigabit Ethernet, Inniband 2.5Gb, 1394b, 393Mb,
786.4 3Mb, 1.572 Gb
Group
Mask
Syntax
MASK:FILTer {OFF|ON|<NR1>}
MASK:FILTer?
Related Com
mands
ACQuire:MODe
Arguments
ON enables the digital lter.
OFF disables the digital lter.
<NR1> = 0 disables the digital lter; any other value enables it.
Examples
MASK:FILTER ON enables the digital lter.
MASK:FILTER? might return :MASK :FILTER 1, indicating that the selected
digital lter will be run on the waveform data.
MASK:HIGHLIGHTHits
This command sets or returns whether or not hits in a mask are highlighted in
different colors than other waveform data. The default is On.
Group
Mask
Syntax
MASK:HIGHLIGHTHits {OFF|ON|<NR1>}
MASK:HIGHLIGHTHits?
Arguments
ON enables the mask:highlighthits function.
OFF disables the m ask:highlighthits function.
<NR1> = 0 disables the mask:highlighthits function; any other value enables it.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-305

Table of Contents

Other manuals for Tektronix DPO70000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO70000 Series and is the answer not in the manual?

Tektronix DPO70000 Series Specifications

General IconGeneral
BrandTektronix
ModelDPO70000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals