Commands Listed in Alphabetical Order
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:PATte rn?
Related Commands
TRIGger:{A|B}:LOGIc:PATtern:INPut:CH<x>, TRIGger:{A|B}:LOGIc:
PATtern:WHEn, TRIGger:{A|B}:LOGIc:PATtern:WHEn:LESSLimit,
TRIGger:{A|B}:LOGIc:PATtern:WHEn:MORELimit
Examples
TRIGGER:A:LOGIC:PATTERN? might return
:TRIGGER:A:LOGIC:PATTERN: INPUT:CH4 X;
:TRIGGER:A:LOGIC:PATTERN: WHEN TRUE; W HEN:LESSLIMIT
5.0000E-9;MORELIMIT 5.0000E-9.
TRIGger:{A|B}:LOGIc:PATtern:INPut:CH<x>
This command sets or queries the A or B logic trigger input for the specified
channel. This command specifies the logic value used when the pattern trigger
detects the threshold level.
This command is equivalent to selecting Logic Pattern from the Trig menu and
then choosing the desired logical input from the channel drop-down list, which is
located in the Input Threshold g roup box.
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:PATte rn:INPut:CH<x> {HIGH|LOW|X}
TRIGger:{A|B}:LOGIc:PATte rn:INPut:CH<x>?
Related Commands
TRIGger:{A|B}:LOGIc:FUNCtion,
TRIGger:{A|B}:LOGIc:INPut:CH<x>,
TRIGger:{A|B}:LOGIc:THReshold:CH<x>
Arguments
HIGH specifies the logic high.
LOW specifies the logic low.
X specifies a “do not care” sta te.
Examples
TRIGGER:A:LOGIC:PATTERN:I NPUT:CH4 HIGH This command sets the A
logic trigger input to logic high for Channel 4 when the logic class is set to
PATtern. When the threshold level is detected, High places a 1 on the Channel 4
input to the selected function.
2-506 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual