Commands Listed in Alphabetical Order
VSROC192 (VSR O
C192/STM64, 1.24416 Gb/s)
Examples
MASK:STANDARD E1COAX selects the E1 Coax standard mask.
MASK:STANDARD? might return :MASK:STANDAR D E1COAX, indicating that the
E1 Coax mask is selecte d as the current mask standard.
MASK:STOPOnviolation
This command sets or returns the stop on violation setting. When enabled, this
command stops waveform acquisitions on the first occurrence of a waveform
violation. MASK:DISplay must be ON for the instrument to detect violations.
Group
Mask
Syntax
MASK:STOPOnviolation {OFF|ON|<NR1>}
MASK:STOPOnviolation?
Arguments
ON stops waveform acquisition on the first occurrence of a mask violation.
OFF turns off mask test stop on violation.
<NR1> = 0 turns off stop on violation; any other value turns on stop on violation.
Examples
MASK:STOPONVIOLATION ON sets the instrument to stop waveform acquisition
on the first occurrence of a waveform violation.
MASK:STOPONVIOLATION? might return :MASK:STOPONVIOLATIO N ON,
indicating that the stops waveform acquisitions on the first occurrence of a
waveform violation is enabled.
MASK:TESt:AUX:COMPLetion
This command sets or returns the test:aux on pass/fail test completion mode.
When enabled, this command causes the instrument to provide a TTL signal at the
Aux:Out port when the mask pass/fail status changes to ‘Failing’.
Group
Mask
Syntax
MASK:TESt:AUX:COMPLetion {OFF|ON|<NR1>}
MASK:TESt:AUX:COMPLetion?
2-324 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual