Commands Listed in Alphabetical Order
TRIGger:A:I2
C:DATa:STARt
DPO7000 Series only: This command sets or queries the d ata start byte. This
byte is only needed if triggering on data. This byte is the first byte that pattern
matching use
s. The byte i s a destination offset from the start of the packe t.
Group
Low Speed Serial Trigger
Syntax
TRIGger:A:I2C:DATa:STARt <NR3>
TRIGger:A:I2C:DATa:STARt?
Arguments
<NR3> specifies the data start byte (offset), with a range of 0 to 65535.
Examples
TRIGGER:A:I2C:DATA:START 0 specifies the I2C data s t art byte offset to 0.
TRIGGER:A:I2C:DATA:START? might return :TRIGG ER:A:I2C:DATA:START
5
, indicating that the I2C data start byte offset is set to 5.
TRIGger:A:I2C:DATa:VALue
DPO7000 Series only: This command sets or queries the binary data string used
for I2C triggering if the trigger condition is DATA or ADDRANDDATA.
Group
Low Speed Serial Trigger
Syntax
TRIGger:A:I2C:DATa:VALue <String>
TRIGger:A:I2C:DATa:VALue?
Arguments
String sets the I2C data value. This value can be 1 to 3 2 bits.
Examples
TRIGGER:A:I2C:DATA:VALUE “1011” sets the I2C data value to 1011.
TRIGGER:A:I2C:DATA:VALUE? might return :TRIGG ER:A:I2C:DATA:VALUE
10111
, indicating that the I2C data value is set to 10111.
TRIGger:A:I2C:FORMat
DPO7000 Series only: This command sets o r queries the display format for the
I2C data value.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-573