Commands Listed in Alphabetical Order
<NR1> =0turnso
ff repeat on completion, and any other integer turns on repeat on
completion.
Examples
MASK:TEST:R
EPEAT ON
causes the instrument to continuously repeat the
pass/fail test.
MASK:TEST:REPEAT? might return :MASK:TEST:REPEAT ON, indicating that
the repeat pass/fail te st on completion is turned on.
MASK:TESt:SAMple
This command sets or returns the minimum number of waveform database
(WfmDB) points the instrument can acquire before it stops a single sequence
acquisition or stops running a m ask test.
Hint: a bigger sample size may allow a greater throughput (more waveforms to
get acquired at a time). However, a very largesamplesizemayslowdownthe
display update. So if you want to speed up the display rate, consider reducing the
sample size.
This command works the same as the ACQuire:NUMSAMples command.
Group
Mask
Syntax
MASK:TESt:SAMple {<NR1>}
MASK:TESt:SAMple?
Arguments
<NR1> the number of points to s ample.
Examples
MASK:TEST:SAMPLE 100000 sets the instrument to acquire 100,000 WfmDB
points.
MASK:TEST:SAMPLE? might return :M ASK:TEST:SAMPLE 100000, indicating
that the repeat pass/fail test on completion is set to 100,000 WfmDB points.
MASK:TESt:SAMple:THReshold
This command sets or returns the minimum number of hits in mask regions
needed to cause the pass/fail status to change from PASSING to
FAILING. This
affects the mask test when the instrument is acquiring in waveform database
(WfmDB) mode.
Group
Mask
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-329