Commands Listed in Alphabetical Order
TRIGger:{A|B
}:PULse:CLAss
This comma nd sets or queries the type of pulse on which to trigger. This
command is equivalent to selecting the setup menu for the pulse type that you
want from the
Trig menu: Glitch Setup, Width Setup, Runt Setup, Timeout Setup,
or Transition Setup.
Group
Trigger
Syntax
TRIGger:{A|B}:PULse:CLAss {GLItch|RUNT|WI Dth|
TRANsition|TIMEOut|WINdow}
TRIGger:{A|B}:PULse:CLAss?
Related Commands
TRIGger:{A|B}:PULse:GLItch?, TRIGger:{A|B}:PULse:RUNT?,
TRIGger:{A|B}:PULse:WIDth?, TRIGger:{A|B}:PULse:TIMEOut?,
TRIGger:{A|B}:PULse:TRANsition?, TRIGger:A:TYPe
Arguments
GLItch triggers when a pulse is found that is of the specified polarity and width.
These are set with the c ommands TRIGger:{A|B}:PULse:GLItch:POLarity and
TRIGger:{A|B}:PULse:GLItch:WIDth.
RUNT triggers when a pulse crosses the first preset voltage threshold but
does not cross the second preset threshold before recrossing the first. The
thresholds are set with the TRIGger:{A|B}:PULse:RUNT:THReshold:LOW and
TRIGger:{A|B}:PULse:RUNT:THReshold:HIGH commands.
WIDth triggers when a pulse is found that has the specified polarity and is either
inside or outside the limits as specified by TRIGger:{A|B}:PULse:WIDth:
LOWLimit and TRIGge
r:{A|B}:PULse:WIDth:HIGHLimit. The polarity is
selected using the TRIGger:{A|B}:PULse:WIDth:POLarity command.
TRANsition trigge
rs when a pulse crosses both thresholds in the same direction
as the specified polarity and the transition time between the two threshold
crossings is grea t er or less than the specified time delta.
TIMEOut triggers when the pulse train stops in the selected state for longer than
the specified time.
WINdow triggers when a pulse is found that meets the conditions
set by the A Event window trigger type, specified by the following
commands: TRIGger:{A|B}:PULse:WINdow:THReshold:HIGH,
TRIGger:{A|B}:PULse:WINdow:THReshold:LOW, TRIGger:{A|B}:PULse:
WINdow:THReshold:BOTh,andTRIGger:{A|B}:PULse:WINdow:WIDTH
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-521