Commands Listed in Alphabetical Order
Related Commands
TRIGger:LVLSr
cpreference, TRIGger:{A|B}:UPPerthreshold:CH<x>
Arguments
ECL specifies the preset ECL high level.
TTL specifies the preset TTL high level.
<NR3> specifies the threshold voltage in user units.
Examples
TRIGGER:A:LOWERTHRESHOLD: CH2 TTL sets the A trigger threshold voltage
for Channel 2 to the TTL low level.
TRIGGER:A:LOWERTHRESHOLD: CH3? might return
:TRIGGER:A:LOWERTHRESHOLD :CH3 1.2000E+00,indi
cating that the A
trigger threshold voltage for Channel 3 is 1.2 V.
TRIGger:{A|B}:PULse? (Query Only)
This query-only command returns the pulse trigger parameters.
Group
Trigger
Syntax
TRIGger:{A|B}:PULse?
Related Commands
TRIGger:{A|B}:EDGE?, TRIGger:A:LOGIc?
Examples
TRIGGER:A:PULSE? might return :TRIGGER:A:PULSE:CLASS
GLITCH;SOURCE CH1; GLI TCH:WIDTH 2.0000E-9;TRIGIF
ACCEPT;POLARITY POSITIVE; POLARITY:CH1
POSITIVE;CH2 POSITIVE;CH3 POSITIVE;CH4
POSITIVE;:TRIGGER:A:PULSE :GLITCH:QUALIFY
OCCURS;:TRIGGER:A:PULSE:W INDOW:TYPE INSIDE;WHEN
OCCURS;WIDTH 2.0000E-9;:TRIGGER:A:PULSE:T RANSITION:DELTA TIME
2.0000E-9;POLARITY POSITIVE;THRESHO LD:HIGH 1.2000;LOW
800.0000E-3;:TRIGGER:A:PU LSE:TRANSITION:WHEN
SLOWERTHAN; :TRIGGER:A:PULSE:WIDTH:LOWLIM IT
2.0000E-9;HIGHLIMIT 2.0000E-9;WHEN WITHIN;POLARITY
POSITIVE;:TRIGGER:A:PULSE :TIMEOUT:POLARITY STAYSHI GH;TIME
2.0000E-9
.
2-520 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual