TRIGGER:A:LOG
IC:PATTERN:WHEN:MORELIMIT 10.0E+00
sets the minimum
time that the selected pattern may hold true (and generate an A logic pattern
trigger) to 10 s.
TRIGGER:A:LOGIC:PATTERN:WH EN:MORELIMIT? might return
:TRIGGER:A:LOGIC:PATTERN:W HEN:MORELIMIT 5.0000E-09, indicating
that the selected pattern must hold true for at least 5 ns to generate an A logic
pattern trigger.
TRIGger:{A|B}:LOGIc:SETHold? (Query Only)
This quer
y-only command returns the clock edg e polarity, voltage threshold and
source input; data voltage threshold and source; and both setup and hold times
for setup and hold v iolation triggering. This command is e quivalent to selecting
Setup/Hold Setup from the Trig menu and then viewing the current setups.
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:SETHol d?
Related Commands
TRIGger:{A|B}:LOGIc:PATtern?, TRIGger:{A|B}:LOGIc:STATE?
Examples
TRIGGER:A:LOGIC:SETHOLD? might return the settings
:TRIGGER:A:LOGIC:SETHOLD:C LOCK:EDGE RISE; THRESHOLD
1.4000;THRESHOLD:CH1 1.4000;CH2 1.2000;CH3 1.20 00;CH4
1.2000;:TRIGGER:A:LOGIC:SE THOLD:CLOCK:SOURCE
CH2;:TRIGGER:A:LOG
IC:SETHOLD:DATA:THRESHOLD
1.4000;THRESHOLD: CH1 1.4000;CH2 1.2000;CH3 1.2000;CH4
1.2000;:TRIGGER:A:LOGIC:SE THOLD :HOLDTIME 2.0000E-9;SETTIME
3.0000E-9;QUALIFY OCCURS
.
TRIGger:{A|B}:LOGIc:SETHold:CLOCk? (Query Only)
This query-only command returns the clock edge polarity, v oltage threshold and
source input for s
etup and hold triggering. This command is equivalent to selecting
Setup/Hold Setup from the Trig menu and then viewing the current clock setups.
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:SETHol d:CLOCk?
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-509