Commands Listed in Alphabetical Order
Arguments
NR1 = 0 disables
immediate state measurement annotation, any other value
enables immediate state measurements.
OFF disables a
nnotation on immediate state measurements.
ON enables annotation on immediate state measurements.
Examples
MEASUREMENT:ANNOTATION:IM MEDSTATE ON enables annotation of immediate
measurements.
MEASUREMENT:ANNOTATION:IM MEDSTATE? might return
:MEASUREMENT:ANNOTATION:I MMEDSTATE 0, indicating that
annotation of immediate measurements is off.
MEASUrement:ANNOTation:NUMX? (Query Only)
This query-only command returns the number of horizontal measurement
annotations currently being displayed.
Group
Measurement
Syntax
MEASUrement:ANNOTation:NU MX?
Examples
MEASUREMENT:ANNOTATION:NU MX? might return
MEASUREMENT:ANNOTATION:NU MX 2, indicating that there are currently 2
horizontal lines drawn on the graticule showing where the measurement specified
by
MEASUREMENT:ANNOTATION:STA TE is being performed.
MEASUrement:ANNOTation:NUMY? (Query Only)
This query-only command returns the number of vertical measurement annotations
currently being displayed.
Group
Measurement
Syntax
MEASUrement:ANNOTation:NU MY?
Examples
MEASUREMENT:ANNOTATION:NU MY? might return
MEASUREMENT:ANNOTATION:NU MY 2, indicating that there are currently 2
vertical lines drawn on the graticule s howing where the measurement specified by
MEASUREMENT:ANNOTATION:ST ATE is
being performed.
2-364 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual