Page 108 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
12.6 Relevel Zone Size
The dead zone is a software-defined area at a floor that the car will stop in when at floor level
and not trigger a relevel. A zone size too small will cause a yo-yoing effect, a zone too large
would hinder the releveling operation and allow the car to remain off level.
The following procedure describes how to relevel zone size.
Navigate to MAIN MENU | SETUP | FLOORS. See Figure 55.
From the FLOORS menu, scroll and select Relevel Zone Size.
Figure 138: FLOORS Menu Relevel Zone Size
From the RELEVEL ZONE SIZE menu, scroll and select the zone size.
Figure 139: RELEVEL ZONE SIZE Menu
Scroll right and press Save.
12.7 Releveling Delay
A delay time is set prior to the releveling process to allow the car to settle before triggering a
releveling operation.
The following procedure describes how to set the relevel delay time.
Navigate to MAIN MENU | SETUP | FLOORS. See Figure 55.
From the FLOORS menu, scroll and select Releveling Delay.
Figure 140: FLOORS Menu Releveling Delay

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals