Output
Description
Regen Reset
Triggers a reset of an active regen fault.
Safety Rescue
Triggers manual rescue in event of power loss.
SS Reset
Cycle power to a faulted soft starter.
Start Motor
Signal to start pump motor.
Start Motor 2
Start pump motor (secondary soft starter).
Valve High DN
Triggers the high speed valve in the down direction.
Valve High Up
Triggers the high speed valve in the up direction.
Valve Insp
Signal to blaine valve controller that the car is attempting an
inspection run.
Valve Level DN
Triggers the leveling speed valve in the down direction.
Valve Level UP
Triggers the leveling speed valve in the up direction.
Valve Low DN
Triggers the low speed valve in the down direction.
Valve Low UP
Triggers the low speed valve in the up direction.
Valve Mid DN
Triggers the medium speed valve in the down direction.
Valve Mid UP
Triggers the medium speed valve in the up direction.
Table 43: Description of Emergency Power Outputs
Output
Description
Lamp On EP
Car is on emergency power operation.
Select 1
Car is on emergency power operation and is recalling or has been
released back into automatic operation.
Select 2
Car is on emergency power operation and is recalling or has been
released back into automatic operation.
Select 3
Car is on emergency power operation and is recalling or has been
released back into automatic operation.
Select 4
Car is on emergency power operation and is recalling or has been
released back into automatic operation.
Select 5
Car is on emergency power operation and is recalling or has been
released back into automatic operation.
Select 6
Car is on emergency power operation and is recalling or has been
released back into automatic operation.
Select 7
Car is on emergency power operation and is recalling or has been
released back into automatic operation.
Select 8
Car is on emergency power operation and is recalling or has been
released back into automatic operation.
Table 44: Description of Fire/Earthquake Outputs
Output
Description
EQ Slow Lamp
Activates when the car is in EQ Hoistway Scan operation.
Fire I Active
Used by Peelle door operator. Active if Fire Phase 1 is active and
recall has not completed.

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals