Hydro:Evolved User Manual
Page 218 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
27.4 CT Insp. Req. IC
If required, an IC inspection can be performed prior to CT inspection.
The following procedure describes how to enable the CT inspection.
Navigate to MAIN MENU | SETUP | MISCELLANEOUS. See Figure 57.
From the MISCELLANEOUS menu, scroll and select CT Insp. Req. IC.
Figure 377: MISCELLANEOUS Menu – CT Insp. Req. IC
From the IC REQ FOR CT menu, scroll and select ON to enable CT inspection.
Figure 378: IC REQ FOR CT Menu
Scroll right and press Save.
27.5 Dis. IdleTrvArrow
The arrow shown on hall call is dependent upon the idle travel arrow. If it is set to ON, the
arrow shows the direction that the car traveled to the floor. If set OFF, the arrow shows the
direction of travel.
The following procedure describes how to disable the travel arrow.
Navigate to MAIN MENU | SETUP | MISCELLANEOUS. See Figure 57.
From the MISCELLANEOUS menu, scroll and select Disable IdleTrvArrow.
Figure 379: MISCELLANEOUS Menu – Disable. IdleTrvArrow