Page #62 background imageLoading...
Page #62 background image
Hydro:Evolved User Manual
Page 28 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
There are two ways the Hall board communicates with the Riser board:
CAN bus via twisted pair
CAT5
The table below lists the Hall Board 10 DIP switch settings.
Table 10: Hall Board 10 DIP Switch Settings
DIP Switch
Functionality
DIP 1
Landing ID 1
DIP 2
Landing ID 2
DIP 3
Landing ID 3
DIP 4
Landing ID 4
DIP 5
Landing ID 5
DIP 6
Landing ID 6
DIP 7
Function ID 1
DIP 8
Function ID 2
DIP 9
Function ID 3
DIP 10
CAN Termination
The table below lists the Hall Board 12 DIP switch settings.
Table 11: Hall Board 12 DIP Switch Settings
DIP Switch
Functionality
DIP 1
Landing ID 1
DIP 2
Landing ID 2
DIP 3
Landing ID 3
DIP 4
Landing ID 4
DIP 5
Landing ID 5
DIP 6
Landing ID 6
DIP 7
Landing ID 7
DIP 8
Function ID 1
DIP 9
Function ID 2
DIP 10
Function ID 3
DIP 11
N/A
DIP 12
CAN Termination
2.6 Valve Board SR3045
The Neutral input signal comes from the EB output from the MR board to the Valve board
which controls when to either open or close the valves.
When valves are open, the oil flows from the cylinder and allows the car to move in either an
up or down direction.

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals