The table below lists the Setup – Group Setup, Flood, and EMS menu structures.
Table 20: Setup – Group Setup, Flood, and EMS Menu Structures
Emergency medical service options
Sets an offset to the bottom landing so hall calls can be
aligned properly for all cars in a group. If car 1 serves
landing 1 and car 2 starts servicing landing 2, then car 2
would have an offset of 1.
Sets the time the car has to respond to a destination
assignment before it temporarily removes itself from the
group and the call is be reassigned. This prevents
excessive delays in answering hall calls due to someone
holding open the car door. If either the dispatch timeout
or dispatch offline are set to zero, this feature is disabled.
Should be set to 0 if only one car is in the group.
Sets the time the car removes itself from the group after
failing to take an assigned call. If either the dispatch
timeout or dispatch offline are set to zero, this feature is
disabled.
Sets the number of X-Reg cars to include in dispatching
XReg Dest Timeout (10 sec)
Sets the time the XReg car has to respond to a destination
assignment before it temporarily removes itself from the
group and the call is be reassigned. This prevents
excessive delays in answering hall calls due to someone
holding open the car door. If either the dispatch timeout
or dispatch offline are set to zero, this feature is disabled.
XReg Dest Offline Timeout (10 sec)
Sets the time the XReg car removes itself from the group
after failing to take an assigned call. If either the dispatch
timeout or dispatch offline are set to zero, this feature is
disabled.
Enables hall call security
Turn ON/OFF which hall board function will have hall call
security
Turn ON/OFF Hall Call security for front landings
Turn ON/OFF Hall Call security for rear landings
Turn ON/OFF which hall board function the car will
respond to for hall calls