Hydro:Evolved User Manual
October 2022 © 2022 Smartrise Engineering, Inc. All Rights Reserved Page 161
From the HALL MEDICAL MASK menu, scroll and select which cars are set for emergency
service calls.
Figure 273: HALL MEDICAL MASK Menu
Scroll right and press Save.
16.10 Hall Rear Door Mask
The hall rear door mask sets which hall boards function as rear door calls. Hall boards that are
configured as rear door calls will be latched.
The following procedure describes how to set hall rear door mask.
Navigate to MAIN MENU | SETUP | GROUP SETUP. See Figure 58.
From the GROUP SETUP menu, scroll and select Hall Rear Door Mask.
Figure 274: GROUP SETUP Menu – Hall Rear Door Mask
From the HALL REAR DOOR MASK menu, scroll and select hall calls that service landings
where only the rear door opens.
Figure 275: HALL REAR DOOR MASK Menu
Scroll right and press Save.
16.11 Errors
The following are possible errors that can occur:
• UNK – The board is uninitialized.
• NONE – The board has no errors.
• POR – The board is starting up.
• WDT – The board stalled and triggered a reset.