Hydro:Evolved User Manual
October 2022 © 2022 Smartrise Engineering, Inc. All Rights Reserved Page 135
From the DOOR TYPE SELECT menu, select the type of door used on the front and rear
landing as applicable.
Figure 227: DOOR TYPE Menu
Scroll right and press Save.
14.25 Lock and CAM Timeout
Sets the timeout which accounts for the delay between CAM activation and locks being made
for manual doors. The units are in 100 ms counts. If set to zero, value defaults to 4 seconds.
The following procedure describes how to set the lockout time for lock and cam.
Navigate to MAIN MENU | SETUP | DOOR SETUP. See Figure 55.
From the DOORS menu, scroll and select Lock and CAM Timeout.
Figure 228: DOORS Menu Lock and CAM Timeout
From the TIMEOUT LOCK AND CAM menu, set the amount of time for the timeout.
Figure 229: TIMEOUT LOCK AND CAM Menu
Scroll right and press Save.
14.26 Retiring CAM
When set to ON, the CAM output controls hall interlocks. When set to OFF, interlocks are
controlled by the door operator.
The following procedure describes how to set the retiring CAM on.
Navigate to MAIN MENU | SETUP | DOOR SETUP. See Figure 55.

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals