Door open limit status. This output turns ON when the door open
limit switch signals the door is open.
Door nudge. After a specified timeout, if the door has not closed,
the doors will move to a nudging state where the PHE is ignored
and the nudging output will turn on.
Safety edge broken status. This output turns ON when the safety
edge or photoeye is broken.
Used by Peelle light curtain to test for photoeye failure prior to
each close attempt.
Used by Peelle door operator. Activates 5 seconds before starting
door close and remains on until doors fully closed.
Table 46: Description of Rear Doors Outputs
Arrival down turns on when the car arrives at a floor then opens
its doors and intends to continue moving down.
Arrival up turns on when the car arrives at a floor then opens its
doors and intends to continue moving up.
Retiring CAM. For swing hall doors and some freight doors, this
output controls the hall locks. This output turns on when the car is
in motion.
Door closed limit status. This output turns ON when the door
closed limit switch signals the door is closed.
Used by Peelle door operator. Triggers door operator fast
open/close where landing and car door movement will occur
simultaneously.
Door open limit status. This output turns ON when the door open
limit switch signals the door is open.
Door nudge. After a specified timeout, if the door has not closed,
the doors will move to a nudging state where the PHE is ignored
and the nudging output will turn on.