October 2022 © 2022 Smartrise Engineering, Inc. All Rights Reserved Page 253
From the MAIN RECALL menu, scroll and select Opening.
Figure 465: MAIN RECALL Menu – Opening
From the MAIN RECALL DOOR menu, scroll and select if the front or rear door opens.
Figure 466: MAIN RECALL DOOR Menu
Scroll right and press Save.
31.3.2 Alternate Recall
Sensors indicate if the fire is at the designated main recall floor. If the fire is on that floor, the
car then travels to a designated alternate landing.
31.3.2.1 Alternate Recall Floor
The following procedure describes how to set the designated landing.
Navigate to MAIN MENU | SETUP | FIRE. See Figure 56.
From the FIRE SERVICE menu, scroll and select Alt Recall.
Figure 467: FIRE SERVICE Menu – Alt Recall
From the ALT RECALL menu, scroll and select Floor.
Figure 468: ALT RECALL Menu – Floor