Hydro:Evolved User Manual
Page 224 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
From the DISABLE OOS menu, scroll and select if out of service is disabled.
Figure 396: DISABLE OOS Menu
Scroll right and press Save.
27.9.2 Hourly Fault Limit
The hourly fault limit is the number of faults allowed per hour prior to the car going out of
service. The car remains out of service until the hour window elapses.
The following procedure describes how to set hourly fault limit.
Navigate to MAIN MENU | SETUP | MISCELLANEOUS. See Figure 57.
From the MISCELLANEOUS menu, scroll and select OOS. See Figure 394.
From the OOS menu, scroll and select Hourly Fault Limit.
Figure 397: OOS Menu – Hourly Fault Limit
From the HOURLY FAULT LIMIT menu, set the number of logged faults allowed per hour.
Figure 398: HOURLY FAULT LIMIT Menu
Scroll right and press Save.
27.9.3 Maximum Starts Per Minute
The maximum starts per minute is the number of times a car starts a run in automatic
operation within the maximum amount of runs per minute. If additional runs are attempted,
the car goes out of service until the hour window elapses.
The following procedure describes how to set the maximum starts per minute.
Navigate to MAIN MENU | SETUP | MISCELLANEOUS. See Figure 57.