1G-7 Fuel System:
Fuel Pump Relay Inspection
B823H11706004
Refer to “Electrical Components Location in Section 0A
(Page 0A-7)”.
Inspect the fuel pump relay in the following procedures:
1) Lift and support the fuel tank. Refer to “Fuel Tank
Removal and Installation (Page 1G-10)”.
2) Remove the fuel pump relay (1).
3) First, check for insulation with the tester between
terminals “A” and “B”. Next, check for continuity
between “A” and “B” with 12 V voltage applied,
positive (+) to terminal “C” and negative (–) to
terminal “D”. If continuity does not exist, replace the
relay with a new one.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Continuity test ( )
Fuel Hose Inspection
B823H11706005
Refer to “Fuel Line Inspection in Section 0B (Page 0B-
10)”.
Fuel Level Gauge Inspection
B823H11706006
Refer to “Fuel Level Gauge Inspection in Section 9C
(Page 9C-6)”.
1
I823H1170027-01
“A”
“B”
“C”
“D”
I718H1170013-01