Commands listed in alphabetical order
Syntax
BUS:B<x>:SPI:
SELect:SOUrce
{CH<x>|CH<x>_D<x>|MATH<x> |REF<x>|REF<x> _D<x>}
BUS:B<x>:SPI:SELect:SOUrc e?
Related Commands
BUS:B<x>:SPI:SELect:POLarity
Arguments
CH<x> designates an analog channel as the buses' SPI Slave Select source.
CH<x>_D<x> designates a digital channel as the buses' SPI Slave Select source.
MATH<x> designates a math waveform as the Slave Select source.
REF<x> designates a ref erence waveform as the Slave Select source.
REF<x> _D<x> specifies a digital reference waveform as the clock source
waveform for the specified SPI bus.
Examples
BUS:B1:SPI:SELECT:SOURCE MATH3 sets the SPI Slave Select source for
the bus B1 to MATH3.
BUS:B1:SPI:SELECT:SOURCE? might return :BUS:B1:SPI:SELECT:SOURCE
CH3
, indicating that the SPI Slave Select source for the bus B1 is set to CH3.
BUS:B<x>:SPI:SELect:THReshold
This command sets or queries the SPI Select (SS) source threshold for the
specified bus. The bus is specified by x.
Conditions
Requires option SR-EMBD.
Group
Bus
Syntax
BUS:B<x>:SPI:SELect:THRes hold <NR3>
BUS:B<x>:SPI:SELect:THRes hold?
Arguments
<NR3> is the SPI Select (SS) source threshold for the specified bus.
Examples
BUS:B1:SPI:SELect:THReshold 50.0e-3 sets the threshold to 50.0 mV.
BUS:B1:SPI:SELect:THReshold? might return
:BUS:B1:SPI:SELECT:THRESHOLD 0.0E+0 indicating the threshold is set to
0.0 V.
2-176 MSO54, MSO56, MSO58, MSO58LP Programmer