Commands listed in alphabetical order
Examples
TRIGGER:A:BUS
:B1:ARINC429A:LABEL:QUALIFIE R LESSTHAN
sets the
label qualifier to less than.
TRIGGER:A:BU
S:B1:ARINC429A:LABEL:QUALI FIER?
might return EQUAL,
indicating that the label qualifier is set to equal.
TRIGger:{A|B}:BUS:B<x>:ARINC429A:LABel:VALue
This command sets or queries the low value when triggering on an ARINC429
label field. The bus number is specified by x. The trigger condition must be set to
LABel or LABELANDDATA.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:AR INC429A:LABel:VALue <QString>
TRIGger:{A|B}:BUS:B<x>:AR INC429A:LABel:VALue?
Arguments
<QString> is the label value.
Examples
TRIGGER:A:BUS:B1:ARINC429 A:LABEL:VALUE "XXXX1010" sets the value
to XXXX1010.
TRIGGER:A:BUS:B1:ARINC429 A:LABEL:VALUE? might return
"XXXXXXXX", indicating that the value is XXXXXXXX.
TRIGger:{A|B}:BUS:B<x>:ARINC429A:SDI:VALue
This command sets or queries the label when triggering on an ARINC429 SDI
field. The bus number is specified by x. The trigger condition must be set to DATa
or LABELANDDATA, and the data format must b e set to DATA.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:AR INC429A:SDI:VALue <QString>
TRIGger:{A|B}:BUS:B<x>:AR INC429A:SDI:VALue?
2-764 MSO54, MSO56, MSO58, MSO58LP Programmer