Commands listed in alphabetical order
Arguments
<NR1> is the num
ber of B trigger events, which can range from 1 to 65,471.
Examples
TRIGGER:B:EVENTS:CO
UNT 4
sets the number of B trigger events to four.
TRIGGER:B:EVENTS:COUNT? might return :TRIGGER:B:E VENTS:COUNT 2,
indicating that two e
vents mus t occur after the A trigger before the B trigger
can occur.
TRIGger:B:RESET (No Q uery Form)
This command sets t
he B reset trigger level to 50%.
Group
Trigger
Syntax
TRIGger:B:RESET SETLevel
Arguments
SETLevel se ts the B rese t trigger level to 50%.
Examples
TRIGger:B:RESET SETLevel sets the B reset trigger level to 50%.
TRIGger:B:RESET:EDGE:COUPling
Sets or queries the trigger coupling for a sequential edge trigger reset when the
Source is set to an analog channel.
Group
Trigger
Syntax
TRIGger:B:RESET:EDGE:COUPl ing {DC|HFRej|LFRej|NOISErej }
TRIGger:B:RESET:EDGE:COUPl ing?
Related Commands
Arguments
DC selects DC trigger coupling.
HFRej selects high frequency low sensitivity.
LFRej selects low frequency low sensitivity.
NOISErej selects DC low sensitivity.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-879