Commands listed in alphabetical order
Arguments
Arguments are i
nstrument buttons.
Examples
FPANEL:PRESS FORC ETRIG emulates pressing the Force trigger button.
FPAnel:TURN
This command is used to emulate a knob turn. The optional NR1 species
the number of clicks where negative values indicate counter clockwise. If not
specied, the default of 1 click is used indicating the knob is turned clockwise
1 click.
Group
Miscellaneous
Syntax
FPAnel:TURN {GPKNOB1|GPKNOB2|HORZPOS|H ORZScale|
PANKNOB|TRIGLevel|VERTPOS |VERTSCALE|ZOOM} [,<NR1>]
Arguments
Arguments are knobs that turn obtained during startup.
<NR1> is the number of clicks to turn the knob.
Examples
FPANEL:TURN TRI GLEVEL ,3 emulates turning the trigger Level knob 3 clicks
in the clockwise direction..
HEADer
This command sets or queries the Response Header Enable State that causes the
instrument to either include or omit headers on query responses.
NOTE. This command does not affect IEEE Std 488.2-1987 Common Commands
(those starting with an asterisk); these commands never return headers. .
Whether the long or short form of header keywords and enumerations are returned
is dependent upon the state of :VERBose.
Group
Miscellaneous
Syntax
HEADer {<NR1>|OFF|ON}
HEADer?
2-338 MSO54, MSO56, MSO58, MSO58LP Programmer