Commands listed in alphabetical order
SEARCH:SEARC
H<x>:TRIGger:A:WINdow:CROSSIng
This command sets or queries the window trigger threshold crossing of the
selected trigger Source. The threshold crossing selection is only effective when
:TRIGger:A:
WINdow:WHEn is INSIDEGreat er or OUTSIDEGreater. The sea rch
number is specied by <x>.
Group
Search and Mark
Syntax
SEARCH:SEARCH<x>:TRIGger: A:WINdow:CROSSIng
{UPPer|LOWer|EITher|NONe}
Arguments
UPPer if :TRIGger:A: WINdow:WHEn is INSIDEGreater, the instrument
triggers when the signal remains between the upper and lower thresholds for
longer than the time limit (
:TRIGger:A:WINdow:WIDTH) and then exits through
the upper threshold. If
:TRIGger:A:WINdow:WHEn is OUTSIDEGreater,the
instrument triggers when the signal remains above the upper threshold for longer
than the time limit (
:TRIGger:A:WINdow:WIDTH) and then crosses downward
through the upper threshold.
LOWer if :TRIGger:A: WINdow:WHEn is INSIDEGreater, the instrument
triggers when the signal remains between the upper and lower thresholds for
longer than the time limit (
:TRIGger:A:WINdow:WIDTH) and then exits through
the lower threshold. If
:TRIGger:A:WINdow:WHEn is OUTSIDEGreater,the
instrument triggers when the signal remains below the lower threshold for longer
than the time limit (
:TRIGger:A:WINdow:WIDTH) and then crosses upwards
through the lower threshold.
EITher if :TRIGger:A:WINdow:WHEn is INSIDEGreater, the instrument
triggers when the signal remains between the upper and lower thresholds for
longer than the time limit (
:TRIGger:A:WINdow:WIDTH) and then exits
through either the upper or lower threshold. If
:TRIGger:A:WINdow:WHEn is
OUTSIDEGreater, the instrument triggers when the signal remains either above
the upper threshold or below the lower threshold for longer than the time limit
(
:TRIGger:A:WINdow:WIDTH) and then crosses a threshold.
NONe if :TRIGger:A:WINdo w:WHEn is INSIDEGreater, the instrument triggers
when the signal remains between the upper and lower thresholds for longer than
the time limit (
:TRIGger:A:WINdow:WIDTH) without crossing through either the
upper or lower threshold. If
:TRIGger:A:WINdow:WHEn is OUTSI DEGreater,
the instrument triggers when the signal remains outside the upper and lower
thresholds for longer than the time limit (
:TRIGger:A:WINdow:WIDTH) without
crossing through either the upper or lower threshold.
Examples
SEARCH:SEARCH1:TRIGger:A: WINdow:CROSSIng LOWER sets the
CROSSING to LOWER.
2-746 MSO54, MSO56, MSO58, MSO58LP Programmer