Commands listed in alphabetical order
Group
Cursor
Syntax
DISplay:WAVEView<x>:CURSo r:CURSOR<x>:FUNCtion
{SCREEN|WAVEFORM| VBArs|HBArs}
DISplay:WAVEView<x>:CURSo r:CURSOR<x>:FUNCtion?
Arguments
HBArs specifies horizontal bar cursors, which measure in vertical units.
VBArs specifies vertical bar cursors, which measure in horizontal units.
SCREE
N specifies both horizontal and vertical bar cursors, which measure in
horizontal and vertical units specified by the Cursor 1 and Cursor 2 Sources. Use
these cursors to measure anywhere in the waveform display area.
WAVEform specifies paired or split cursors in YT display format for measuring
waveform amplitude and time. In XY and XYZ format, these cursors indicate the
amplitude positions of an XY pair (Ch1 vs Ch2 voltage, where Ch1 is the X axis
and Ch2 is the Y axis) relative to the trigger.
Examples
DISPLAY:WAVEVIEW1:CURSOR: CURSOR1:FUNCTION VBArs selects the
vertical bar cursor type for the specified waveview and cursor.
DISPLAY:WAVEVIEW1:CURSOR: CURSOR1:FUNCTION? might return
:DISPLAY:WAVEVIEW1:CURSOR :CURSOR1:FUNCTION HBArs indicating that
the specified cursor is set to HBArs.
DISplay:WAVEView<x>:CURSor:CURSOR<x>:HBArs:APOSition
Sets or queries the HBARs vertical A position of the specified cursor in the
specified waveview.
NOTE.
WAVEView<x>
is the specified waveview and must be
WAVEView1
.
Cursor<x>
is the specified cursor and must be
CURSOR1
.
Group
Cursor
Syntax
DISplay:WAVEView<x>:CURSo r:CURSOR<x>:HBArs:APOSition <NR3>
DISplay:WAVEView<x>:CURSo r:CURSOR<x>:HBArs:APOSition?
Arguments
<NR3> is the vertical cursor A position of the specified cursor in the specified
waveview. 0.0 divisions is center, 5 .0 top of the waveview, and -5.0 the bottom
of the waveview.
2-290 MSO54, MSO56, MSO58, MSO58LP Programmer