Commands listed in alphabetical order
POWer:POWer<
x>:SWITCHINGRIPPLE:INPUTSOurce
This command sets or queries the input source for switching ripple measurement
in the specified power measurement badge. The power measurement badge
is specified b
yx.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:SWITCHINGR IPPLE:INPUTSOurce {CH<x> | MATH<x> |
REF<x>}
POWer:POWer<x>:SWITCHINGR IPPLE:INPUTSOurce?
Arguments
CH<x> = A channel specifier; <x> is 1 through 8 and is limited by the number
of FlexChannels in your instrument.
MATH<x> = A math waveform specifier; <x> is ≥1.
REF<x> = A reference waveform specifier; <x> is ≥1.
Examples
POWer:POWer1:SWITCHINGRIP PLE:INPUTSOurce CH5 sets the input source
for switching ripple measurement as CH5 for the power measurement badge
Power 1.
POWer:POWer<x>:SWITCHINGRIPPLE:LFREQuency
This command sets or queries the switching frequency for switching ripple
measurement in the specified power m easurement badge. The power measurement
badge is specified by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:SWITCHINGR IPPLE:LFREQuency <NR1>
POWer:POWer<x>:SWITCHINGR IPPLE:LFREQuency?
Arguments
<NR1> ranges from 50 to 1000000
2-594 MSO54, MSO56, MSO58, MSO58LP Programmer