Commands listed in alphabetical order
TRIGger:{A|B
}:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue
When the Ethernet trigger condition is set to TCPHeader, this command specifies
the 32-bit acknowledgement number that is to be used in the trigger (along with
the destinat
ion and source port addresses and the sequence number). The d efault
is all X’s (don’t care). The bus number is specified by <x>.
Conditions
Requires the SR-ENET Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:ET HERnet:TCPHeader:ACKnum:VALue
<QString>
TRIGger:{A|B}:BUS:B<x>:ET HERnet:TCPHeader:ACKnum:VALue?
Related Commands
TRIGger:{A|B}:BUS:B<x>:ETHERnet:CONDition
TRIGger:{A|B}:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
TRIGger:{A|B}:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
TRIGger:{A|B}:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue
Arguments
<QString> is a quoted string of up to 3 2 characters where the allowable
characters are 0, 1, and X. The bits specified in the quoted string replace the least
significant bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet :TCPHeader:ACKnum:VALue
"XXXXXXXXXXXXXXXXXXXX0000 1000"
sets the acknowledg
ement number to be
used in the trigger to hexadecimal
XXXXXX08.
TRIGger:A:BUS:B1:ETHERnet :TCPHeader:ACKnum:VA
Lue?
might
return
:TRIGGER:A:BUS:B1:ETHERNET:T CPHEADER:ACKNUM:VALUE
"XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXX"
indicating the value is set to
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
When the Ethernet trigger condition is set TCPH eader, this command specifies
the 16–bit destination port address value that is
to be used in the trigger (along
with the a cknowledgement value, source port address and the sequence number).
The default is all X’s (don’t care). The bus number is specified by <x>.
2-790 MSO54, MSO56, MSO58, MSO58LP Programmer