Commands listed in alphabetical order
MEASUrement:
MEAS<x>:GATing:MIDRef
This command sets or queries the gating mid ref value when the gating type is
logic. Measurements are specified by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:GATing :MIDRef <NR3>
MEASUrement:MEAS<x>:GATing :MIDRef?
Arguments
<NR3> is the mid ref value for gating.
Examples
MEASUrement:MEAS1:GATin
g:MIDRef 1.0E+0
sets the gating midref to 1.0.
MEASUrement:MEAS1:GATing:M IDRef? might return
:MEASUREMENT:MEAS1:GAT
ING:MIDREF 0.0E+0
indicating the
midref value is set to 0.0.
MEASUrement:MEAS<x>:GATing:SEARCHSource
This command sets or que
riesthegatingsearchsourcewhenthegatingtypeis
search. The measurement number is specified by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:GATing :SEARCHSource SEARCH1
Arguments
SEARCH1 is the gating source for search gating.
Examples
MEASUrement:MEAS1:GATing:S EARCHSource SEARCH1 sets the gating
search source to SEARCH1.
MEASUrement:MEAS1:GATing:S EARCHSource? might return
:MEASUREMENT:MEAS1:GATING: SEARCHSOURCE SEARCH1 indicating the
gating search source is SEARCH1.
MEASUrement:MEAS<x>:GLOBalref
This command sets or queries the refe rence levels global flag for the measurement.
Measurements are specified by x.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-455