Commands listed in alphabetical order
Syntax
TRIGger:{A|B}
:BUS:B<x>:MIL1553B:STATus:BI T:BUSY
{ONE|ZERo|NOCARE}
TRIGger:{A|B}:BUS:B<x>:MI L1553B:STATus:BIT:BUSY?
Arguments
ONE filters status words to only match those where the BUSY bit has a value of 1.
ZERo filters status words to only match those where the BUSY bit has a value of 0.
NOCARE disables filtering of status words on the BUSY bit.
Examples
TRIGGER:A:BUS:B1:MIL1553B :STATUS:BIT:BUSY ONE specifies filtering
status words for those where the BUSY bit has a value of 1.
TRIGGER:A:BUS:B1:MIL1553B :STATUS:BIT:BUSY? might return NOCARE,
indicating that status words are not being filteredbasedontheBUSYbitvalue.
TRIGger:{A|B}:BUS:B<x>:MIL1553B:STATus:BIT:DBCA
This command sets or queries the value of the dynamic bus control acceptance bit
(DBCA bit, bit 18) in a status word for a MIL-STD-1553 b us to triggering on.
The bus number is specified by x. The trigger condition must be set to STATus.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MI L1553B:STATus:BIT:DBCA
{ONE|ZERo|NOCARE}
TRIGger:{A|B}:BUS:B<x>:MI L1553B:STATus:BIT:DBCA?
Arguments
ONE filters status words to only match those where the DBCA bit has a value of 1.
ZERo filte rs stat
us words to only match those where the DBCA bit has a value of 0.
NOCARE disables filtering of status words on the DBCA bit.
Examples
TRIGGER:A:BUS:B1:MIL1553B :STATUS:BIT:DBCA ONE specifies filtering
status words for those where the DBCA bit has a value of 1.
TRIGGER:A:BUS:B1:MIL1553B :STATUS:BIT:DBCA? might return NOCARE,
indicating that status words are not being filtered based on the DBCA bit value.
2-824 MSO54, MSO56, MSO58, MSO58LP Programmer