Commands listed in alphabetical order
Syntax
TRIGger:{A|B}
:BUS:B<x>:MIL1553B:TIMe:LESS Limit
<NR3>
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:TIMe:LESSLimit?
Related Commands
TRIGger:{A|B}:BUS:B<x>:MIL1553B:TIMe:QUALifier
Arguments
<NR3> is a floating point number that specifies the lower bound for measuring
remote terminal response time (RT) or the inter-message gap (IMG) in seconds.
Examples
TRIGGER:A:BUS:B1:MIL1553B: TIME:LESSLIMIT 2.0000e-6 sets the lower
bound for comparison to 2 microseconds.
TRIGGER:A:BUS:B1:MIL1553B: TIME:LESSLIMIT? might return 4.0000E-6,
indicating that the lower bound for c omparison is s et to 4 microseconds.
TRIGger:{A|B}:BUS:B<x>:MIL1553B:TIMe:MORELimit
This command sets or queries the upper limit to be used when triggering on
response time / inter message gap time for a MIL-STD-1553 bus. The bus number
is specified by x. The trigger condition must be set to TIMe.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:TIMe:MORELimit <NR3>
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:TIMe:MORELimit?
Related Commands
TRIGger:{A|B}:BUS:B<x>:MIL1553B:TIMe:QUALifier
Arguments
<NR3> is a floating point number that specifies the upper bound for measuring
remote terminal response time (RT) or the inter-message gap (IMG) in seconds.
Examples
TRIGGER:A:BUS:B1:MIL1553B: TIME:MORELIMIT 15.0000e-6 sets the
upper bound for comparison to 15 microseconds.
TRIGGER:A:BUS:B1:MIL1553B: TIME:MORELIMIT? might return 12.0000E-6,
indicating that the upper bound for comparison is set to 12 microseconds.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-829