Commands listed in alphabetical order
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:CA N:FD:BRSBit {ONE|ZERo|NOCARE}
TRIGger:{A|B}:BUS:B<x>:CA N:FD:BRSBit?
Arguments
ONE filters CAN FD packets to only match those where the BRS bit has a value of
1 (fast data enabled).
ZERo filters CAN FD packets to only match those where the BRS bit has a value
of 0 (fast data disabled).
NOCARE disables fi ltering of CAN FD packets on the BRS bit.
Examples
TRIGGER:A:BUS:B1:CAN:FD:B RSBit ONE speci fies fi ltering CAN FD packets
for those where the BRS bit has a value of 1.
TRIGGER:A:BUS:B1:CAN:FD:B RSBIT? might return NOCARE, indicating that
CANFDpacketsarenotbeingfiltered based on the BRS bit value.
TRIGger:{A|B}:BUS:B<x>:CAN:FD:ESIBit
This command sets or queries the value of the error state indicator bit (ESI bit)
for a CAN bus to triggering on. The bus number is specified by x. The trigger
condition must be set to FDBITS, and the CAN standard must be FDISO or
FDNONISO.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:CA N:FD:ESIBit {ONE|ZERo|NOCARE}
TRIGger:{A|B}:BUS:B<x>:CA N:FD:ESIBit?
Arguments
ONE filters CAN FD packets to only match those where the ESI bit has a value
of 1 (recessive).
ZERo filters CAN FD packets to only match those where the ESI bit has a value
of 0 (dominant).
NOCARE disables filtering of CAN FD packets on the ESI bit.
Examples
TRIGGER:A:BUS:B1:CAN:FD:E SIBit ONE speci fies fi ltering CAN FD packets
for those where the ESI bit has a value of 1.