Commands listed in alphabetical order
MEASUrement:
AUTOset (No Query Form)
This command performs an analysis jitter autoset.
Group
Measurement
Syntax
MEASUrement:AUTOset EXECute
Examples
MEASUREMENT:AUTOSET EXECute performs an analysis jitter autoset.
MEASUrement:CH<x>:REFLevels:ABSolute:FALLHigh
This command sets or queries the value used as the high reference level of the
falling edge when the source ref level method is set to absolute. The channel
number is specified by x.
Group
Measurement
Syntax
MEASUrement:CH<x>:REFLeve ls:ABSolute:FALLHigh <NR3 >
MEASUrement:CH<x>:REFLeve ls:ABSolute:FALLHigh?
Arguments
<NR3> is the high reference level, and is the zero percent lev
el when
MEASUrement:IMMed:REFLevel:METHod is set to Absolute.
Examples
MEASUREMENT:CH2:REFLEVELS :ABSOLUTE:FALLHIGH 1.5 sets the h igh
referencelevelofthefallingedgeto1.5V.
MEASUREMENT:CH2:REFLEVELS :ABSOLUTE:FALLHIGH? might return
:MEASUREMENT:CH2:REFLEVEL S:ABSOLUTE:FALLHIGH 1.000 0 indicating
that the high reference level of the falling edge is 1.0 V.
MEASUrement:CH<x>:REFLevels:ABSolute:FALLLow
This command sets or queries the value used as the low reference level of the
falling edge when the source ref level method is set to absolute. The channel
number is specified by x.
Group
Measurement
2-382 MSO54, MSO56, MSO58, MSO58LP Programmer