Commands listed in alphabetical order
Syntax
POWer:POWer<x
>:RESUlts:ALLAcqs:MAXimum?
<QString>
Arguments
<QString> = parame ters of the measurements. The details of the p arameters for
the Power measurements are listed below:
For Power Quality measurement, the parameters are "TRUEPWR" | "APPPWR"
| "REPWR" | "PWRFACTOR" | "PHASE" | "PWRFREQ" | "ICFACTOR" |
"VCFACTOR" | "IRMS" | "VRMS".
For Switching Loss measurement, the parameters are "TONENRG" | "TONLOSS"
| "TOFFENRG" | "TOFFLOSS" | "CONDENRG" | "CONDLOSS" | "TTLLOSS" |
"TTLENRG".
For dV by dt m easurement, the parameter is “DVBYDT”.
For dI by dt measurement, the parameter is “DIBYDT”.
For SOA measurement, the parameter is “SOAHITSCNT”.
For Line Ripple measurement, the parameters are “LRIPRMS” | “LRIPPKPK”.
For Swi
tching Ripple measurement, the parameters a re “SWRIPRMS” |
“SWRIPPKPK”.
For Cy
cle Period measurement, the parameters is “PRIO D”.
For Cycle Frequency measurement, the parameters is “FREQ”.
For Positive Duty Cycle measurement, the parameters is “PDUTY”.
For Negative Duty Cycle measurement, the para meters is “NDUTY”.
For Positive Pulse Width measurement, the parameters is “PPULSE”.
For Negative Pulse Width measurement, the parameters is “NPULSE”.
Fo
r C ycle Amplitude measurement, the parameters is “AMPL”.
For Cycle Peak–Peak measurement, the parameters is “PKPK”.
For Cycle Top measurement, the parameters is “HIGH”.
For Cycle Base measurement, the parameters is “LOW”.
For Cycle Max measurement, the parameters is “MAX”.
For Cycle Min measurement, the parameters is “MIN”.
Examples
POWer:POWer1:RESUlts:CURR entacq:MAXimum? "TONEnrg" might return
9.91E+37, indicating the maximum value of Ton Energy for all acquisitions.
2-562 MSO54, MSO56, MSO58, MSO58LP Programmer