@Remote Setting
Settings Relevant to the Service Contract
Change the necessary settings for the following SP modes if the customer has entered a service contract.
• You must select one of the counter methods (developments/prints) in accordance with the contract
(SP5-045-001).
Counting method
SP No. Function Default
SP5-045-001 Specifies if the counting method used in meter
charge mode is based on developments or prints.
"1": Prints
Service Tel. No. Setting
SP No. Function Default
SP5-812-001
through 004
SP5-812-002 programs the service station fax
number. The number is printed on the counter list
when the meter charge mode is selected. This lets
the user fax the counter data to the service station.
Settings for @Remote Service
• Prepare and check the following check points before visiting the customer site. For details, ask the
@Remote key person.
Check points before making @Remote settings
1. The setting of SP5-816-201 (Remote Service: Regist: Status) in the mainframe must be "0".
2. Print the SMC with SP5-990-002 (SP Print Mode: SP (Mode Data List)) and then check if a
device ID2 (SP5-811-003) must be correctly programmed.
• 6 spaces must be put between the 3-digit prefix and the following 8-digit number (e.g.
xxx______xxxxxxxx).
• ID2 (SP5-811-003) and the serial number on the machine serial decal pasted at the rear
must be the same (e.g. ID2: A01______23456789 = serial No. A0123456789)
@Remote Setting
185