PREPARATION
SM 1-1 J001/J003
Installation
1. INSTALLATION
1.1 PREPARATION
1.1.1 ENVIRONMENT
Put the machine in a location with these requirements:
Temperature Range:
10°C to 32°C (50°F to 89.6°F)
Humidity Range: 15% to 80% RH
Ambient Illumination: Less than 1,500 Lux (never expose to direct sunlight).
Ventilation: More than 30 m
3
/hr/person in the work area
Ambient Dust: Less than 0.10 mg/m
3
40
20
60
80
100
0
10 20
32
%Rh
10C (50F),
80%
27C (80.6F), 80%
25C (77F), 70%
32C (89.6F),
54%
32C (89.6F), 15%
25C (77F), 30%
10C (50F), 15%
15C (59F), 30%
G707I900.WMF
Recommended range
A
llowed ran
g
e
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA