475
Selecting the State After Powering On (Start Up Menu)
Chapter 18 System Setup (System)
Selecting the State at Start-up
1
In the status area of the System >Start Up menu, select
the device to which the settings are to apply.
2
In the <Start Up Mode> group, select one of the
following modes.
Resume: When this is on, Resume mode is enabled.
Custom: When this is on, Custom mode is enabled.
The Resume mode is only valid when a switcher or
control panel is selected for the setting.
3
When Custom mode is selected, in each of the
<Setup> group and <Initial Status> group, select one
of the following.
User: When this is on, user-defined settings are used
for the Setup or Initial Status settings. For the
method of saving the user-defined settings, see the
next item.
Factory: When this is on, factory default settings are
used for the Setup or Initial Status settings.
4
To confirm the settings, press [Execute]. If you want
to cancel the setting changes without saving them,
press [Clear].
When [Execute] is pressed, a confirmation message
appears.
5
Select [Yes].
Saving User-Defined Settings
Saving the Setup settings
1
After selecting the devices to which the settings apply
to, in the System >Start Up menu, press [Setup
Define].
A confirmation message appears.
2
Press [Yes].
This saves the setup settings for the selected devices in
non-volatile memory within the respective devices.
For details about the settings which will be saved,
see“Data Saved by [Setup Define] and [Initial Status
Define]” (page 589).
Saving the Initial Status settings
1
After selecting the devices to which the settings apply
to, in the System >Start Up menu, press [Init Status
Define].
A confirmation message appears.
2
Press [Yes].
This saves the initial status settings other than the
“setup” settings for the selected devices in non-volatile
memory within the respective devices.
For details about the settings which will be saved, see
“Data Saved by [Setup Define] and [Initial Status
Define]” (page 589).
Setting Automatic Loading of
Register Data at Power On (Autoload
Function)
To have specified data read in at power on, in the System
>Start Up menu, press [Power On File Load], turning it on.
This enables the autoload function.
When the autoload function is enabled, a directory
“PWON_LD” appears in the corresponding File menu.
About saving data which can be loaded by the autoload
function, see “Saving Files Recalled by Autoload” (page
466).
Notes

Table of Contents

Other manuals for Sony MVS-7000X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony MVS-7000X and is the answer not in the manual?

Sony MVS-7000X Specifications

General IconGeneral
BrandSony
ModelMVS-7000X
CategorySwitch
LanguageEnglish

Related product manuals