607
Error Messages
Appendix (Volume 2)
Error Messages Shown in the Error Information Menu
If a file transfer related error occurs, the Error Information
menu appears to the following error messages.
Cannot find the File Name Data, please load
the File Name Data first (–21).
2565:Frame Memory >External Device >Restore from DDR/VTR
In the above menu, when [Restore] is pressed, this message
appears if the file list was not loaded.
Set Time/Date
Error: Wrong Format. 7317: Engineering Setup >System >Maintenance
In the above menu, an incorrect date and time was specified.
Specify the date and time correctly.
Trim
The Start TC or Stop TC is not properly set. 2522:Frame Memory >Clip >Play
In the above menu, when [Trim] is pressed, this message appears if
neither Start TC not Stop TC is set.
2522:Frame Memory >Clip >Play
In the above menu, when [Trim] is pressed, this message appears if
the interval between Start TC (or Clip Begin) and Stop TC (or Clip
End) is the entire clip.
2522:Frame Memory >Clip >Play
In the above menu, when [Trim] is pressed, this message appears if
the Start TC (or Clip Begin) value is greater than the Stop TC (or
Clip End) value.
This file is locked. 2522:Frame Memory >Clip >Play
In the above menu, when [Trim] is pressed, this message appears if
the file is locked.
This file is using for playback. 2522:Frame Memory >Clip >Play
In the above menu, when [Trim] is pressed, this message appears if
the file is being played back.
Warning
No Switcher information available.
Please confirm “Network Configuration” on
Page 7311.
When starting up the menu system, the switcher is not present in
the system information. Check the Data LAN connections, and in
Menu 7311: Engineering Setup >System >Network Config, retry
[Auto Config].
This operation will be cancelled, because the
register is locked.
Please change the register status to be
unlocked first.
6211.1: Effect >Master Timeline >Store >Edit
6311.1: Snapshot >Master Snapshot >Store >Edit
6411.1: Shotbox >Register >Store >Edit
In the above menus, an attempt was made to store in a locked
register. Unlock the register before carrying out the store.
Warning (System Config)
Illegal Network Config Information (Page
7311)
When starting up the menu system, if the system information read
from the control panel is not correct, one of these messages, that
corresponds to the situation appears.
Following the message, use Menu 7311: Engineering Setup
>System >Network Config or 7312: Engineering Setup >System
>System Config to retry the operation.
Illegal Panel Assign Information for Dual
Simul Operation (Page 7312)
No Panel Assign Information (Page 7312)
No Switcher Assign Information (Page 7312)
No System Operation Mode Information
(Page 7312)
No DME Channel Information
Icon Message Description