Table 24: Component Detailed Operational Status Commands
Operational Mode CommandComponent
show chassis cfebCFEB
show chassis ethernet-switchEthernet switch
show chassis fanFEB
show chassis febFEB
show chassis fpcFPC
show chassis routing-engineRouting Engine
show chassis febFEB
show chassis scbSCB
show chassis sfmSFM
show chassis ssbSSB
show chassis spmbSPMB
show chassis spmb sibsSIB
show chassis ethernet-switchControl Board (Ethernet switch)
Related
Documentation
Basic Router Component Monitoring Method on page 51•
• Checklist for Monitoring the Craft Interface on page 249
• Checking the Craft Interface Environmental Status on page 256
Gather Component Alarm Information
When you obtain information about component alarms and error messages, you determine
when a problem with a component first appeared and the details of the situation.
To gather component alarm information:
1.
Display the Current Router Alarms on page 67
2.
Display Error Messages in the Messages Log File on page 112
3.
Display Error Messages in the Chassis Daemon Log File on page 113
Display the Current Router Alarms
Purpose To determine the details of the alarms and when they first appeared in the component.
67Copyright © 2012, Juniper Networks, Inc.
Chapter 3: Method and Tools for Monitoring Router Components