CIP REV 04 710-002649 AG5779
PEM 0 Rev 03 740-001243 LK16612 Power Entry Module
PEM 1 Rev 03 740-001243 LK16604 Power Entry Module
PCG 0 REV 07 710-001568 HF1164
PCG 1 REV 07 710-001568 HF1159
Routing Engine 0 REV 01 740-003239 AARCHOO RE-2.0
Routing Engine 1 REV 01 740-003239 AARCHOO RE-2.0
MCS 0 REV 11 710-001226 AV4425
MCS 1 REV 11 710-001226 HD2842
[...Output truncated...]
Meaning The command output displays the MCS slot number, revision level, part number, and
serial number. Give this information to the Juniper Networks Technical Assistance Center
(JTAC) if an MCS fails.
Related
Documentation
Checklist for Monitoring Redundant MCSs on page 675•
Monitoring Redundant MCS Status
To monitor redundant MCSs, do one of the following:
1.
Check the Redundant MCS Environmental Status on page 678
2.
Check the Redundant MCS Status from the Craft Interface on page 679
3.
Check the Redundant MCS LED Status on page 680
Check the Redundant MCS Environmental Status
Purpose To determine the environmental status of the redundant MCS from the command line.
Action To check the redundant MCS status, use the following command:
user@host> show chassis environment mcs
Sample Output
user@host> show chassis environment mcs
MCS 0 status:
State Online Master
Temperature 0 degrees C / 32 degrees F
Power:
3.3 V 3318 mV
5.0 V 5001 mV
12.0 V 11833 mV
5.0 V bias 4991 mV
8.0 V bias 8341 mV
CMB Revision 12
FPGA Revision 12
MCS 1 status:
State Present
Power:
3.3 V 3308 mV
5.0 V 5013 mV
12.0 V 11809 mV
5.0 V bias 4952 mV
Copyright © 2012, Juniper Networks, Inc.678
M Series and T Series Routers Monitoring and Troubleshooting Guide