Understanding Redundant Cooling System Components
•
Redundant Cooling System Components Overview on page 624
•
M5 and M10 Router Redundant Cooling System Components on page 625
•
M7i Router Redundant Cooling System Components on page 626
•
M10i Router Redundant Cooling System Components on page 627
•
M20 Router Redundant Cooling System Components on page 628
•
M40 Router Redundant Cooling System Components on page 629
•
M40e and M160 Router Redundant Cooling System Components on page 630
•
M120 Router Redundant Cooling System Components on page 632
•
M320 Router Redundant Cooling System Components on page 633
•
T320 Router Redundant Cooling System Components on page 635
•
T640 Router Redundant Cooling System Components on page 636
•
T1600 Router Redundant Cooling System Components on page 638
•
TX Matrix Router Redundant Cooling System Components on page 640
•
TX Matrix Plus Router Redundant Cooling System Components on page 642
Redundant Cooling System Components Overview
Inspect the router redundant cooling system components to ensure that air is flowing
through the router to cool the components installed in the router chassis. If the router
temperature exceeds a critical level, the router automatically shuts down.
Redundant cooling system components are more than just one fan or impeller installed
in a router to ensure that the air is flowing through the router and that an acceptable
temperature is maintained to cool the components installed in the chassis.
Table 143 on page 624 and Table 144 on page 625 describe the redundant cooling system
components and characteristics for each routing platform.
Table 143: M Series Router Redundant Cooling System Components Characteristics
M320M160M120M40eM40M20M10iM7i
M5 and
M10
Cooling
System
Component
2 front
1 rear
1 lower2 front
2 rear
13 front
1 rear
211 fan tray
with 4
fans
Fan tray
Cooled by
air flowing
through
the chassis
Cooled
by air
flowing
through
the
chassis
Cooled
by air
flowing
through
the
chassis
_22___Power supply
integrated fan
Copyright © 2012, Juniper Networks, Inc.624
M Series and T Series Routers Monitoring and Troubleshooting Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
BrandJuniper
ModelM Series
CategoryNetwork Router
LanguageEnglish

Related product manuals