Page #467 background image
user@host>show chassis environment
Sample Output
T640@host>show chassis environment
Class Item Status Measurement
Temp PEM 0 Absent
PEM 1 OK 32 degrees C / 89 degrees F
SCG 0 OK 37 degrees C / 98 degrees F
SCG 1 Absent
Routing Engine 0 OK 35 degrees C / 95 degrees F
Routing Engine 1 Absent
CB 0 OK 36 degrees C / 96 degrees F
SIB 0 OK 44 degrees C / 111 degrees F
SIB 1 OK 50 degrees C / 122 degrees F
SIB 2 OK 50 degrees C / 122 degrees F
SIB 3 OK 50 degrees C / 122 degrees F
SIB 4 OK 52 degrees C / 125 degrees F
[...Output truncated...]
Meaning The command output displays each component installed in the router, including the
operating status and temperature.
If there is a problem with the SIB status, you can display more detailed environmental
information with the following command:
user@host>show chassis environment sib
user@host> show chassis environment sib
SIB 0 status:
State Spare
Temperature 44 degrees C / 111 degrees F
Power:
GROUND 0 mV
1.8 V 1807 mV
2.5 V 2478 mV
3.3 V 3308 mV
1.8 V bias 1797 mV
3.3 V bias 3284 mV
5.0 V bias 5018 mV
8.0 V bias 7440 mV
SIB 1 status:
State Online
Temperature 50 degrees C / 122 degrees F
Power:
GROUND 0 mV
1.8 V 1814 mV
2.5 V 2485 mV
3.3 V 3321 mV
1.8 V bias 1794 mV
3.3 V bias 3313 mV
5.0 V bias 5028 mV
8.0 V bias 7553 mV
SIB 2 status:
[...Output truncated...]
SIB 3 status:
[...Output truncated...]
SIB 4 status:
[...Output truncated...]
423Copyright © 2012, Juniper Networks, Inc.
Chapter 16: Monitoring the SIBs

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
Product SeriesM Series
TypeNetwork Router
ManufacturerJuniper Networks
ThroughputVaries by model
Operating SystemJUNOS
Switching capacityVaries by model
Supported InterfacesATM
Routing CapacityVaries by model
Forwarding PerformanceVaries by model
Maximum Number of InterfacesVaries by model
Power SupplyRedundant power supplies available
Line rateVaries by interface type
Key FeaturesAdvanced routing protocols
RedundancyRedundant power supplies
DimensionsVaries by model
WeightVaries by model
MemoryVaries by model
StorageVaries by model
Environmental ConditionsOperating temperature: Typically 0°C to 40°C, Humidity: 10% to 90% non-condensing

Related product manuals