EasyManuals Logo
Home>Juniper>Network Router>M Series

Juniper M Series User Manual

Juniper M Series
812 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #265 background imageLoading...
Page #265 background image
Meaning The command output displays the current FPC alarms, including the time the alarm
occurred, the severity level, and the alarm description. At the command line, you see the
following FPC error messages:
Too many unrecoverable errors
Too many recoverable errors
From the router craft interface LCD screen, you see the following:
Slot x: errors
Check for FPC alarms on the router craft interface. You can physically look at the craft
interface or use the show chassis craft-interface command. When a red or yellow alarm
occurs, the craft interface goes into alarm mode. Alarm mode preempts idle mode,
displaying a message to alert you of serious alarm conditions. In alarm mode, the screen
displays the following information:
+--------------------+
|myrouter |
|1 Alarm active |
|R: Slot 2:errors |
| |
+--------------------+
The craft interface output provides the following information:
• First line—Name of the router.
• Second line—Number of alarms active on the router.
• Third and fourth lines—Individual alarms, with the most severe condition shown first.
Each line indicates whether the alarm is a red (R) or yellow (Y) alarm.
Displaying FPC Error Messages in the System Log File
Purpose Gather FPC error messages from the system log file.
To determine the details of the FPC error messages in the system log file.
Action To check for FPC error messages in the system log messages file, use the following
command:
user@host> show log messages | match fpc
Check for error messages at least 5 minutes before and after an FPC alarm occurs.
Sample Output
The following output displays when you browse through the messages log file using the
time and date stamp to look for error messages that occur 5 minutes before and after
the FPC event:
user@host> show log messages
Mar 10 09:20:31 cls-edge-02 ssb RDP: Keepalive timeout for
rdp.(scb:chassis).(fpc1:36865) (elapsed 5595)
Mar 10 09:20:33 cls-edge-02 ssb SSB(0): Slot 0, serial number S/N BD9709.
Mar 10 09:20:37 cls-edge-02 ssb BCHIP 1: SRAM test failed.
Mar 10 09:20:37 cls-edge-02 ssb CM(0): Slot 1: B-chip diagnostics failed
221Copyright © 2012, Juniper Networks, Inc.
Chapter 7: Monitoring FPCs

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
BrandJuniper
ModelM Series
CategoryNetwork Router
LanguageEnglish

Related product manuals