EasyManuals Logo
Home>Juniper>Network Router>M Series

Juniper M Series User Manual

Juniper M Series
812 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #763 background imageLoading...
Page #763 background image
NOTE: We recommend that both Routing Engines have the same
configuration.
To display the current SFM redundancy configuration:
1. Enter configuration mode using the following command:
user@host# configure
2. Go to the [edit chassis redundancy] hierarchy level.
3. Show the SFM configuration using the following command:
user@host# show
Related
Documentation
Checklist for Monitoring Redundant SSBs on page 715•
Displaying Redundant SSB Hardware Information
Purpose To obtain information about the redundant SSB hardware.
Action To display the SSB hardware information, use the following command:
user@host> show chassis hardware
Sample Output
user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
[...Output truncated...]
SSB slot 0 REV 01 710-001951 AD5904 Internet Processor II
SSB slot 1 N/A N/A N/A backup
[...Output truncated...]
Meaning The command output displays the SSB version level, part number, serial number, and
description.
Related
Documentation
Checklist for Monitoring Redundant SSBs on page 715•
Monitor Redundant SSB Status
To monitor the SSB:
1.
Display the Redundant SSB Environmental Status on page 720
2.
Display the Redundant SSB Detailed Status on page 720
3.
Check the Redundant SSB LEDs on page 721
719Copyright © 2012, Juniper Networks, Inc.
Chapter 38: Monitoring Redundant SSBs

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper M Series and is the answer not in the manual?

Juniper M Series Specifications

General IconGeneral
BrandJuniper
ModelM Series
CategoryNetwork Router
LanguageEnglish

Related product manuals